DRAC: Added redfish management interface issue

Added a known issue for a bug where using the iDRAC redfish management
interface to set the boot device on a server that is configured to
UEFI boot results in the iDRAC returning an error.

Change-Id: I082563862e326bc292afc897e7a50dec7d084e9f
(cherry picked from commit 7f814058f0)
This commit is contained in:
Christopher Dearborn 2020-04-20 15:34:14 -04:00 committed by Aija Jaunteva
parent 86aabe049a
commit d19fcbcd2b
1 changed files with 21 additions and 0 deletions

View File

@ -622,3 +622,24 @@ To resolve this issue, increase the timeout to 90 seconds by setting the retry c
[agent]
post_deploy_get_power_state_retries = 18
Redfish management interface failure to set boot device
-------------------------------------------------------
When using the ``idrac-redfish`` management interface with certain iDRAC
firmware versions (at least versions 2.70.70.70, 4.00.00.00, and
4.10.10.10) and attempting to set the boot device on a baremetal server
that is configured to UEFI boot, the iDRAC will return the following
error::
Unable to Process the request because the value entered for the
parameter Continuous is not supported by the implementation.
To work around this issue, set the ``force_persistent_boot_device`` parameter
in ``driver-info`` on the node to ``Never`` by running the following command
from the command line:
.. code-block:: bash
openstack baremetal node set --driver-info \
force_persistent_boot_device=Never ${node_uuid}