openstack-manuals/doc/common/tables/cinder-storwize.xml

87 lines
3.3 KiB
XML

<?xml version='1.0' encoding='UTF-8'?>
<para xmlns="http://docbook.org/ns/docbook" version="5.0">
<!-- Warning: Do not edit this file. It is automatically
generated and your changes will be overwritten.
The tool to do so lives in openstack-doc-tools repository. -->
<table rules="all" xml:id="config_table_cinder_storwize">
<caption>Description of IBM Storwise driver configuration options</caption>
<col width="50%"/>
<col width="50%"/>
<thead>
<tr>
<th>Configuration option = Default value</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<th colspan="2">[DEFAULT]</th>
</tr>
<tr>
<td>storwize_svc_allow_tenant_qos = False</td>
<td>(BoolOpt) Allow tenants to specify QOS on create</td>
</tr>
<tr>
<td>storwize_svc_connection_protocol = iSCSI</td>
<td>(StrOpt) Connection protocol (iSCSI/FC)</td>
</tr>
<tr>
<td>storwize_svc_flashcopy_timeout = 120</td>
<td>(IntOpt) Maximum number of seconds to wait for FlashCopy to be prepared. Maximum value is 600 seconds (10 minutes)</td>
</tr>
<tr>
<td>storwize_svc_iscsi_chap_enabled = True</td>
<td>(BoolOpt) Configure CHAP authentication for iSCSI connections (Default: Enabled)</td>
</tr>
<tr>
<td>storwize_svc_multihostmap_enabled = True</td>
<td>(BoolOpt) Allows vdisk to multi host mapping</td>
</tr>
<tr>
<td>storwize_svc_multipath_enabled = False</td>
<td>(BoolOpt) Connect with multipath (FC only; iSCSI multipath is controlled by Nova)</td>
</tr>
<tr>
<td>storwize_svc_npiv_compatibility_mode = False</td>
<td>(BoolOpt) Indicate whether svc driver is compatible for NPIV setup. If it is compatible, it will allow no wwpns being returned on get_conn_fc_wwpns during initialize_connection</td>
</tr>
<tr>
<td>storwize_svc_stretched_cluster_partner = None</td>
<td>(StrOpt) If operating in stretched cluster mode, specify the name of the pool in which mirrored copies are stored.Example: "pool2"</td>
</tr>
<tr>
<td>storwize_svc_vol_autoexpand = True</td>
<td>(BoolOpt) Storage system autoexpand parameter for volumes (True/False)</td>
</tr>
<tr>
<td>storwize_svc_vol_compression = False</td>
<td>(BoolOpt) Storage system compression option for volumes</td>
</tr>
<tr>
<td>storwize_svc_vol_easytier = True</td>
<td>(BoolOpt) Enable Easy Tier for volumes</td>
</tr>
<tr>
<td>storwize_svc_vol_grainsize = 256</td>
<td>(IntOpt) Storage system grain size parameter for volumes (32/64/128/256)</td>
</tr>
<tr>
<td>storwize_svc_vol_iogrp = 0</td>
<td>(IntOpt) The I/O group in which to allocate volumes</td>
</tr>
<tr>
<td>storwize_svc_vol_rsize = 2</td>
<td>(IntOpt) Storage system space-efficiency parameter for volumes (percentage)</td>
</tr>
<tr>
<td>storwize_svc_vol_warning = 0</td>
<td>(IntOpt) Storage system threshold for volume capacity warnings (percentage)</td>
</tr>
<tr>
<td>storwize_svc_volpool_name = volpool</td>
<td>(StrOpt) Storage system storage pool for volumes</td>
</tr>
</tbody>
</table>
</para>