ceilometer/ceilometer/cli.py

191 lines
6.0 KiB
Python
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

#!/usr/bin/env python
# -*- coding: utf-8 -*-
#
# Copyright 2012-2014 Julien Danjou
#
# Author: Julien Danjou <julien@danjou.info>
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
"""Command line tool for creating meter for Ceilometer.
"""
import logging
import sys
import eventlet
# NOTE(jd) We need to monkey patch the socket and select module for,
# at least, oslo.messaging, otherwise everything's blocked on its
# first read() or select(), thread need to be patched too, because
# oslo.messaging use threading.local
eventlet.monkey_patch(socket=True, select=True, thread=True)
from oslo.config import cfg
from ceilometer.alarm import service as alarm_service
from ceilometer.api import app
from ceilometer.central import manager as central_manager
from ceilometer import collector
from ceilometer.compute import manager as compute_manager
from ceilometer import notification
from ceilometer.openstack.common import context
from ceilometer.openstack.common import importutils
from ceilometer.openstack.common import service as os_service
from ceilometer.openstack.common import timeutils
from ceilometer import pipeline
from ceilometer import sample
from ceilometer import service
from ceilometer import storage
from ceilometer import transformer
OPTS = [
cfg.StrOpt('evaluation_service',
default='ceilometer.alarm.service.SingletonAlarmService',
help='Class to launch as alarm evaluation service.'),
]
cfg.CONF.register_opts(OPTS, group='alarm')
cfg.CONF.import_opt('time_to_live', 'ceilometer.storage',
group='database')
LOG = logging.getLogger(__name__)
def alarm_notifier():
service.prepare_service()
os_service.launch(alarm_service.AlarmNotifierService()).wait()
def alarm_evaluator():
service.prepare_service()
eval_service = importutils.import_object(cfg.CONF.alarm.evaluation_service)
os_service.launch(eval_service).wait()
def agent_central():
service.prepare_service()
os_service.launch(central_manager.AgentManager()).wait()
def agent_compute():
service.prepare_service()
os_service.launch(compute_manager.AgentManager()).wait()
def agent_notification():
service.prepare_service()
launcher = os_service.ProcessLauncher()
launcher.launch_service(
notification.NotificationService(),
workers=service.get_workers('notification'))
launcher.wait()
def api():
service.prepare_service()
srv = app.build_server()
srv.serve_forever()
def collector_service():
service.prepare_service()
launcher = os_service.ProcessLauncher()
launcher.launch_service(
collector.CollectorService(),
workers=service.get_workers('collector'))
launcher.wait()
def storage_dbsync():
service.prepare_service()
storage.get_connection_from_config(cfg.CONF).upgrade()
def storage_expirer():
service.prepare_service()
if cfg.CONF.database.time_to_live > 0:
LOG.debug(_("Clearing expired metering data"))
storage_conn = storage.get_connection_from_config(cfg.CONF)
storage_conn.clear_expired_metering_data(
cfg.CONF.database.time_to_live)
else:
LOG.info(_("Nothing to clean, database time to live is disabled"))
def send_sample():
cfg.CONF.register_cli_opts([
cfg.StrOpt('sample-name',
short='n',
help='Meter name.',
required=True),
cfg.StrOpt('sample-type',
short='y',
help='Meter type (gauge, delta, cumulative).',
default='gauge',
required=True),
cfg.StrOpt('sample-unit',
short='U',
help='Meter unit.'),
cfg.IntOpt('sample-volume',
short='l',
help='Meter volume value.',
default=1),
cfg.StrOpt('sample-resource',
short='r',
help='Meter resource id.',
required=True),
cfg.StrOpt('sample-user',
short='u',
help='Meter user id.'),
cfg.StrOpt('sample-project',
short='p',
help='Meter project id.'),
cfg.StrOpt('sample-timestamp',
short='i',
help='Meter timestamp.',
default=timeutils.utcnow().isoformat()),
cfg.StrOpt('sample-metadata',
short='m',
help='Meter metadata.'),
])
service.prepare_service()
# Set up logging to use the console
console = logging.StreamHandler(sys.stderr)
console.setLevel(logging.DEBUG)
formatter = logging.Formatter('%(message)s')
console.setFormatter(formatter)
root_logger = logging.getLogger('')
root_logger.addHandler(console)
root_logger.setLevel(logging.DEBUG)
pipeline_manager = pipeline.setup_pipeline(
transformer.TransformerExtensionManager(
'ceilometer.transformer',
),
)
with pipeline_manager.publisher(context.get_admin_context()) as p:
p([sample.Sample(
name=cfg.CONF.sample_name,
type=cfg.CONF.sample_type,
unit=cfg.CONF.sample_unit,
volume=cfg.CONF.sample_volume,
user_id=cfg.CONF.sample_user,
project_id=cfg.CONF.sample_project,
resource_id=cfg.CONF.sample_resource,
timestamp=cfg.CONF.sample_timestamp,
resource_metadata=cfg.CONF.sample_metadata and eval(
cfg.CONF.sample_metadata))])