Os-brick NVMeoF connector multipathing spec
Native multipathing DeviceMapper "multipathing" / sync replication Interaction between these and connector RAID feature Implements: blueprint nvmeof-multipath Change-Id: I863238f619cb809df7243e6d4317f6ff64c0e883
This commit is contained in:
parent
7464b781cf
commit
6a3ab81771
|
@ -0,0 +1,359 @@
|
||||||
|
..
|
||||||
|
This work is licensed under a Creative Commons Attribution 3.0 Unported
|
||||||
|
License.
|
||||||
|
|
||||||
|
http://creativecommons.org/licenses/by/3.0/legalcode
|
||||||
|
|
||||||
|
===================
|
||||||
|
NVMeoF Multipathing
|
||||||
|
===================
|
||||||
|
|
||||||
|
https://blueprints.launchpad.net/cinder/+spec/nvmeof-multipath
|
||||||
|
|
||||||
|
Extend the NVMeoF connector to support two types of multipathing:
|
||||||
|
|
||||||
|
* Native NVMeoF multipathing
|
||||||
|
* DeviceMapper based multipathing
|
||||||
|
|
||||||
|
At the time of writing, only TCP and RDMA protocols are supported and
|
||||||
|
contemplated by the spec (so it does not contemplate the case for other
|
||||||
|
transport protocols such as FC).
|
||||||
|
|
||||||
|
|
||||||
|
Problem description
|
||||||
|
===================
|
||||||
|
|
||||||
|
Currently the NVMeoF connector only supports single pathed connections.
|
||||||
|
|
||||||
|
The problem description can be summed up by the statement:
|
||||||
|
A single pathed connection is a single point of failure.
|
||||||
|
|
||||||
|
For resiliency, and to catch up with industry standards, support for
|
||||||
|
multi pathed connections is needed, mitigating the single point of failure.
|
||||||
|
|
||||||
|
Another potential benefit is performance while maintaining replication, such
|
||||||
|
as in cases where there is synchronous replication on the backend, and the
|
||||||
|
multipath mechanism can switch on failure.
|
||||||
|
|
||||||
|
This can be done in either of two ways:
|
||||||
|
|
||||||
|
NVMeoF ANA (Asynchronous Namespace Access) is the NVMeoF native way of doing
|
||||||
|
multipathing, and it offers an interesting set of features.
|
||||||
|
A spec is available for more under-the-hood details [1]_.
|
||||||
|
|
||||||
|
Using DeviceMapper for multipathing is an industry standard approach (while
|
||||||
|
NVMeoF ANA support is not yet) with connections such as iSCSI, and can be
|
||||||
|
equally utilized with NVMeoF connections.
|
||||||
|
The goal of DM component of this spec's implementation is to bring the NVMeoF
|
||||||
|
connector up to speed with using DeviceMapper for multipathed connections.
|
||||||
|
|
||||||
|
|
||||||
|
Use Cases
|
||||||
|
=========
|
||||||
|
|
||||||
|
Whether via native multipath or DeviceMapper, the use case is the ability to
|
||||||
|
expose multipathed connections to volumes, mitigating connection single point
|
||||||
|
of failure and improving performance.
|
||||||
|
|
||||||
|
For example, an NVMeoF volume has two paths (portals) and a multipath
|
||||||
|
connection is established to it. If one of the paths breaks (such as in a
|
||||||
|
partial network failure) - the attached device would remain functional,
|
||||||
|
whereas with single pathed connections, the device would become unavailable
|
||||||
|
to the host it was attached to.
|
||||||
|
|
||||||
|
|
||||||
|
Proposed change
|
||||||
|
===============
|
||||||
|
|
||||||
|
The multipathing implementation will be broken up into its two main component
|
||||||
|
features - Native and DM multipathing:
|
||||||
|
|
||||||
|
Phase 1 (Native)
|
||||||
|
----------------
|
||||||
|
|
||||||
|
The NVMeoF connector will check the host's multipath capability and report
|
||||||
|
it in the connector properties passed to the volume driver, this will also
|
||||||
|
allow any driver / backend specific handling.
|
||||||
|
|
||||||
|
The value of `/sys/module/nvme_core/parameters/multipath` can be `Y` or `N` -
|
||||||
|
this should be returned as a True or False `nvme_native_multipath` property in
|
||||||
|
`get_connector_properties` method from the `NVMeOFConnector` connector class.
|
||||||
|
|
||||||
|
The "new" NVMeoF connector API (introduced in Wallaby) supports passing
|
||||||
|
multiple portals for the same NVMeoF device. Currently only the first
|
||||||
|
successful connection is established.
|
||||||
|
|
||||||
|
In multipath mode, the portals connection method should simply connect to
|
||||||
|
all portals by running the `nvme connect` cli command for each one.
|
||||||
|
|
||||||
|
The NVMe system under the hood will create invisible devices for each of the
|
||||||
|
portal connections, and expose a single multipath device on top of them.
|
||||||
|
|
||||||
|
It should be noted that the native multipath spec requires the target portals
|
||||||
|
to expose the device under the same target NQN and namespace id for multipath
|
||||||
|
to happen. (This is the backend's responsibility and should be transparent to
|
||||||
|
OpenStack code)
|
||||||
|
|
||||||
|
Finally, the new device will be matched by its uuid as is already implemented
|
||||||
|
in the baseline single path connector.
|
||||||
|
|
||||||
|
The connection information for a native multipath volume will look like:
|
||||||
|
|
||||||
|
.. code-block:: python
|
||||||
|
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid...',
|
||||||
|
'target_nqn': '...somenqn...',
|
||||||
|
'portals': [
|
||||||
|
('10.1.1.1', 4420, 'tcp'),
|
||||||
|
('10.1.1.2', 4420, 'tcp')
|
||||||
|
]
|
||||||
|
}
|
||||||
|
|
||||||
|
Regarding `enforce_multipath` - it is a DeviceMapper multipathing parameter
|
||||||
|
and it will not have any interaction with the native NVMe multipathing.
|
||||||
|
|
||||||
|
Phase 2 (DeviceMapper)
|
||||||
|
----------------------
|
||||||
|
|
||||||
|
For DeviceMapper multipathing, use `dm_replicas` in the connection information
|
||||||
|
to specify all the replicas. This approach allows for multiple NQNs for one
|
||||||
|
synced volume, which is often a requirement for DM-based multipathing.
|
||||||
|
|
||||||
|
`dm_replicas` cannot be used together with `volume_replicas` which is for RAID
|
||||||
|
replication only. The drivers should know not to pass that. If both are
|
||||||
|
passed, the operation should fail.
|
||||||
|
|
||||||
|
As in the baseline connector, connect to all `dm_replicas` (it is worth
|
||||||
|
mentioning that each replica could have multiple portals, essentially allowing
|
||||||
|
this DeviceMapper aggregation to run on top of native multipath devices)
|
||||||
|
|
||||||
|
Once connections are established, DeviceMapper will handle the multipathing
|
||||||
|
under the hood (should be transparent to OpenStack code)
|
||||||
|
|
||||||
|
DeviceMapper needs to recognize that two devices should be "merged"
|
||||||
|
It does so based on device id information
|
||||||
|
Therefore, it is the responsibility of the backend to expose devices with
|
||||||
|
id information that conforms to the device matching requirements
|
||||||
|
of DeviceMapper.
|
||||||
|
|
||||||
|
Since DeviceMapper recognizes two devices should be "merged" based on device
|
||||||
|
id information (udev?) - it is the responsiblity of the backend to handle its
|
||||||
|
exposed devices to conform to the requirement.
|
||||||
|
|
||||||
|
The connection information for a DeviceMapper multipath volume will look like:
|
||||||
|
|
||||||
|
.. code-block:: python
|
||||||
|
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid...',
|
||||||
|
'dm_replicas': [
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid1...',
|
||||||
|
'target_nqn': '...somenqn1...',
|
||||||
|
'portals': [('10.1.1.1', 4420, 'tcp')]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid2...',
|
||||||
|
'target_nqn': '...somenqn2...',
|
||||||
|
'portals': [('10.1.1.2', 4420, 'tcp')]
|
||||||
|
}
|
||||||
|
]
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
|
Connector API Summary
|
||||||
|
---------------------
|
||||||
|
|
||||||
|
With this proposal, there will be multiple replication and/or multipath mode
|
||||||
|
permutations of operation for the connector:
|
||||||
|
- Single pathed connection
|
||||||
|
- Native multipathed connection
|
||||||
|
- RAID connection (single or multipathed)
|
||||||
|
- DeviceMapper connection (single or native multipath)
|
||||||
|
|
||||||
|
Note: RAID on top of DM is not allowed as it is inconsistent with the
|
||||||
|
connection information API (and would need an unnecessary overcomplication of
|
||||||
|
it as well as the physical implementation). It could theoretically be added
|
||||||
|
one day based on need, but it is overkill on multiple levels.
|
||||||
|
|
||||||
|
Single path connection information for cinder driver:
|
||||||
|
|
||||||
|
.. code-block:: python
|
||||||
|
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid...',
|
||||||
|
'target_nqn': '...somenqn...',
|
||||||
|
'portals': [('10.1.1.1', 4420, 'tcp')]
|
||||||
|
}
|
||||||
|
|
||||||
|
Connection information for cinder driver that supports native multipathed
|
||||||
|
connections (os-brick will iterate them if a single path connection is
|
||||||
|
requested):
|
||||||
|
|
||||||
|
.. code-block:: python
|
||||||
|
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid...',
|
||||||
|
'target_nqn': '...somenqn...',
|
||||||
|
'portals': [
|
||||||
|
('10.1.1.1', 4420, 'tcp'),
|
||||||
|
('10.1.1.2', 4420, 'tcp')
|
||||||
|
]
|
||||||
|
}
|
||||||
|
|
||||||
|
For DeviceMapper, the example below is given with no native multipath for the
|
||||||
|
replica devices. For these replica devices to do native multipathing, portals
|
||||||
|
for each of each device's paths should be specified in the `portals` list.
|
||||||
|
|
||||||
|
Connection information for DeviceMapper:
|
||||||
|
|
||||||
|
.. code-block:: python
|
||||||
|
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid...',
|
||||||
|
'dm_replicas': [
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid1...',
|
||||||
|
'target_nqn': '...somenqn1...',
|
||||||
|
'portals': [('10.1.1.1', 4420, 'tcp')]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
'vol_uuid': '...someuuid2...',
|
||||||
|
'target_nqn': '...somenqn2...',
|
||||||
|
'portals': [('10.1.1.2', 4420, 'tcp')]
|
||||||
|
}
|
||||||
|
]
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
|
Alternatives
|
||||||
|
============
|
||||||
|
|
||||||
|
Both alternative for NVMeoF multipathing that I am aware of are described
|
||||||
|
in this spec: Native and DeviceMapper
|
||||||
|
|
||||||
|
Data model impact
|
||||||
|
=================
|
||||||
|
|
||||||
|
None
|
||||||
|
|
||||||
|
REST API impact
|
||||||
|
===============
|
||||||
|
|
||||||
|
None
|
||||||
|
|
||||||
|
Security impact
|
||||||
|
===============
|
||||||
|
|
||||||
|
Same as the baseline NVMeoF connector:
|
||||||
|
|
||||||
|
* Sudo executions of `nvme`
|
||||||
|
* | Needs access for reading of root filesystem paths such as:
|
||||||
|
| `/sys/class/nvme-fabrics/...`
|
||||||
|
| `/sys/class/block/...`
|
||||||
|
|
||||||
|
|
||||||
|
Active/Active HA impact
|
||||||
|
=======================
|
||||||
|
|
||||||
|
None
|
||||||
|
|
||||||
|
Notifications impact
|
||||||
|
====================
|
||||||
|
|
||||||
|
None
|
||||||
|
|
||||||
|
Other end user impact
|
||||||
|
=====================
|
||||||
|
|
||||||
|
None
|
||||||
|
|
||||||
|
Performance Impact
|
||||||
|
==================
|
||||||
|
|
||||||
|
The main benefit is of increased I/O while maintaining replication - such as
|
||||||
|
in a synchronous replication active-passive failover multipath configuration.
|
||||||
|
|
||||||
|
One performance impact should happen during attachments on the host, where
|
||||||
|
now multiple NVMeoF devices (rather than just one) would need to be connected,
|
||||||
|
and a new device exposed on top of them.
|
||||||
|
|
||||||
|
Depending on the mode of multipath connection (for example active-active vs
|
||||||
|
active-passive) - there could be an increase in network resource usage for
|
||||||
|
the multipath device io.
|
||||||
|
|
||||||
|
|
||||||
|
Other deployer impact
|
||||||
|
=====================
|
||||||
|
|
||||||
|
None
|
||||||
|
|
||||||
|
Developer impact
|
||||||
|
================
|
||||||
|
|
||||||
|
Driver developers that want to use NVMeoF will need to be aware of the
|
||||||
|
connector API - specifically the connection_information spec described
|
||||||
|
|
||||||
|
It is also worth mentioning that storage backends (although transparent to
|
||||||
|
OpenStack code) will need to keep in mind the system level requirements
|
||||||
|
for whichever multipath mode they use (Native or DeviceMapper)
|
||||||
|
|
||||||
|
|
||||||
|
Implementation
|
||||||
|
==============
|
||||||
|
|
||||||
|
Assignee(s)
|
||||||
|
-----------
|
||||||
|
|
||||||
|
* Zohar Mamedov (zoharm)
|
||||||
|
* Anyone Else
|
||||||
|
|
||||||
|
Work Items
|
||||||
|
----------
|
||||||
|
|
||||||
|
Phase 1 (Native):
|
||||||
|
|
||||||
|
* Connector properties check kernel supports native multipath
|
||||||
|
|
||||||
|
* Establish all (multiple) necessary connections to multipath volume and ensure
|
||||||
|
proper device is exposed.
|
||||||
|
|
||||||
|
|
||||||
|
Phase 2 (DeviceMapper):
|
||||||
|
|
||||||
|
* Ensure all sync replicated devices are connected.
|
||||||
|
|
||||||
|
* Ensure the proper DeviceMapper device is exposed.
|
||||||
|
|
||||||
|
|
||||||
|
Dependencies
|
||||||
|
============
|
||||||
|
|
||||||
|
Baseline dependencies are same as baseline single pathed connector:
|
||||||
|
relevant nvmeof kernel modules, and nvme-cli
|
||||||
|
|
||||||
|
For native NVMe multipathing, the kernel needs to support it
|
||||||
|
|
||||||
|
For DeviceMapper multipathing, DeviceMapper needs to be operational
|
||||||
|
|
||||||
|
|
||||||
|
Testing
|
||||||
|
=======
|
||||||
|
|
||||||
|
Unit tests.
|
||||||
|
Also there is an upcoming gate job that will use LVM to test NVMeoF (where
|
||||||
|
multipath testing for it can be included there)
|
||||||
|
|
||||||
|
|
||||||
|
Documentation Impact
|
||||||
|
====================
|
||||||
|
|
||||||
|
Document the new connection_information API described in this spec - especially
|
||||||
|
for drivers to be able to follow and use it.
|
||||||
|
|
||||||
|
|
||||||
|
References
|
||||||
|
==========
|
||||||
|
|
||||||
|
.. [1] ANA Spec - Section 8.1.3: https://nvmexpress.org/wp-content/uploads/NVMe-NVM-Express-2.0a-2021.07.26-Ratified.pdf
|
Loading…