This work is licensed under a Creative Commons Attribution 3.0 Unported
|
||||
License.
|
||||
|
||||
http://creativecommons.org/licenses/by/3.0/legalcode
|
||||
|
||||
====================
|
||||
NUMA-aware vSwitches
|
||||
====================
|
||||
|
||||
https://blueprints.launchpad.net/nova/+spec/numa-aware-vswitches
|
||||
|
||||
vSwitches such as `Open vSwitch`_ (with kernel or DPDK datapath), `Lagopus`_,
|
||||
or `Contrail DPDK vRouter`_ all have some level of NUMA affinity. This can
|
||||
occur because they use one or more physical network interfaces, usually
|
||||
connected via PCIe, or they use userspace processes that are affined to a given
|
||||
NUMA node. This NUMA affinity is not currently taken into account when
|
||||
creating an instance. This can result in up to a 50% performance drop [1]_.
|
||||
|
||||
.. _Open vSwitch: http://www.openvswitch.org/
|
||||
.. _Lagopus: http://www.lagopus.org/
|
||||
.. _Contrail DPDK vRouter: https://www.juniper.net/documentation/en_US/contrail4.1/topics/concept/dpdk-with-vrouter-vnc-40.html
|
||||
|
||||
|
||||
Problem description
|
||||
===================
|
||||
|
||||
In :doc:`/specs/kilo/implemented/input-output-based-numa-scheduling`, nova
|
||||
tackled the problem of NUMA affinity for PCIe devices when using the libvirt
|
||||
driver. This was done by utilizing the NUMA information for these PCIe devices
|
||||
that was provided by libvirt. However, the use of software switching solutions
|
||||
complicates matters compared to switching that is done in hardware. In these
|
||||
cases, we do not pass through entire PCI devices or virtual functions but
|
||||
rather a VIF object. Nonetheless, the vSwitch will utilize physical hardware to
|
||||
access physical networks and will have an affinity to specific NUMA nodes based
|
||||
on this. This NUMA affinity is not currently accounted for, which can result in
|
||||
cross-NUMA node traffic and significant packet processing performance
|
||||
penalties.
|
||||
|
||||
.. important::
|
||||
|
||||
This spec focuses solely on traffic between instances and physical NICs or
|
||||
"physical to virtual (PV)" traffic. Traffic between instances, or "virtual
|
||||
to virtual (VV)" traffic, is not within the scope of this spec.
|
||||
|
||||
Worked Example: OVS-DPDK
|
||||
------------------------
|
||||
|
||||
For those interested in the nitty-gritty of how this works, let's use an
|
||||
example using one possible vSwitch solution, OVS-DPDK. Consider the following
|
||||
network topology:
|
||||
|
||||
.. figure:: /_images/numa-aware-vswitches-1.png
|
||||
:width: 90%
|
||||
|
||||
In the above, we have two guests, each with a number of interfaces, along with
|
||||
a number of host interfaces. When using OVS-DPDK, the guest interfaces would
|
||||
typically be ``dpdkvhostuser`` or ``dpdkvhostuserclient`` ports [2]_, while the
|
||||
physical network interfaces in the host would be ``dpdk`` ports [3]_. Each of
|
||||
these ports has a number of transmit (Tx) and receive (Rx) queues to actually
|
||||
move packets to and from each interface.
|
||||
|
||||
OVS-DPDK uses a number of Poll Mode Driver processes (PMDs) [4]_ to do the
|
||||
actual packet processing and each queue is assigned to a PMD. If DPDK was
|
||||
compiled with ``libnumactl`` and ``CONFIG_RTE_LIBRTE_VHOST_NUMA=y`` [5]_, this
|
||||
assignment is NUMA aware and a queue will be assigned to the same NUMA node as
|
||||
either:
|
||||
|
||||
- The physical network interface the queue is from, for a ``dpdk`` interface
|
||||
- One of the NUMA nodes associated with the guest, for a ``dpdkvhostuser`` or
|
||||
``dpdkvhostuserclient`` interface
|
||||
|
||||
If multiple queues exist (i.e. multi-queue), assigning is done per queue,
|
||||
ensuring that an individual PMD does not become a bottleneck. Where multiple
|
||||
PMDs exist for a given NUMA node, as is often the case, assigning is done in a
|
||||
round-robin fashion. If there is no local (in the sense of NUMA locality) PMD
|
||||
to service the queue, the queue will be assigned to a remote PMD.
|
||||
|
||||
So, let's further build upon the above example and add this NUMA affinity into
|
||||
the mix. We will say there are two NUMA nodes and both the guests and the NICs
|
||||
are split between these nodes. This gives us something like so:
|
||||
|
||||
.. figure:: /_images/numa-aware-vswitches-2.png
|
||||
:width: 90%
|
||||
|
||||
What we want to avoid is cross-NUMA node traffic. We're not particularly
|
||||
concerned with VM <-> VM traffic (more on this in a bit), so such traffic would
|
||||
probably look something like this:
|
||||
|
||||
.. figure:: /_images/numa-aware-vswitches-3.png
|
||||
:width: 90%
|
||||
|
||||
.. note::
|
||||
|
||||
In OVS-DPDK, egress traffic (VM -> Phy) is not particularly costly as the
|
||||
PMD dequeuing packets from the guest queue will be located on the same NUMA
|
||||
node as the guest queue itself. Meanwhile, the enqueue onto the physical
|
||||
network interface's queue is efficient thanks to DMA. However, the return
|
||||
path is much more costly as the enqueue to the guests queue cannot benefit
|
||||
from DMA.
|
||||
|
||||
This is the root cause of the issue: clearly the guest should have been put on
|
||||
the same NUMA node as the NIC it's using, as seen below. This is what we wish
|
||||
to resolve with this spec.
|
||||
|
||||
.. figure:: /_images/numa-aware-vswitches-4.png
|
||||
:width: 90%
|
||||
|
||||
Use Cases
|
||||
---------
|
||||
|
||||
* As a user, I want to ensure I'm getting the maximum benefit from my highly
|
||||
tuned, high-performance vSwitch solution
|
||||
|
||||
* As an operator, I don't want to revert to custom hacks like dynamically
|
||||
adjusting `vcpu_pin_set`__ just so I can deliver the performance my customers
|
||||
demand.
|
||||
|
||||
__ https://docs.openstack.org/nova/queens/configuration/config.html#DEFAULT.vcpu_pin_set
|
||||
|
||||
Proposed change
|
||||
===============
|
||||
|
||||
As we want to provide a generic solution that works for multiple network
|
||||
backends, the solution should be built upon *neutron* and its concepts.
|
||||
*neutron* does not expose things like Open vSwitch's bridges, but rather
|
||||
provides network objects like networks, subnets, and ports. Ports aren't
|
||||
particularly helpful to us as we're not attaching a given port directly to the
|
||||
guest. Instead, we will utilize networks or, more specifically, networks that
|
||||
utilize physical NICs. There are two types of network *technology* in play:
|
||||
*flat* and *VLAN*, a.k.a. L2 *physical* or *non-tunneled* networks, and *GRE*
|
||||
or *VXLAN*, a.k.a. L3 *tunneled* networks.
|
||||
|
||||
.. note::
|
||||
|
||||
Others mechanisms, such as *OPLEX* (Cisco proprietary), are supported in
|
||||
addition to *VLAN*, *VXLAN* et al. through the use of non-default Neutron
|
||||
backends. These are considered out-of-scope for this spec. We also consider
|
||||
*local*, which does not provide external network connectivity, out-of-scope.
|
||||
|
||||
.. note::
|
||||
|
||||
The network *technologies* discussed here are distinct from the network
|
||||
*types* neutron offers, such as *provider* networks [6]_ [7]_ and
|
||||
*tenant* networks [8]_ [9]_, and are different again from the
|
||||
*architectures* available, such as *pre-created networking* or
|
||||
*self-serviced networking*. The network *types* and *architectures* focus
|
||||
more on *who* can configure a given network (users for tenant networks,
|
||||
admin for both) and *where* that configuration is found (for provider
|
||||
networks, generally configuration files, but an admin can explicitly
|
||||
override this). The table below illustrates this.
|
||||
|
||||
.. list-table::
|
||||
:header-rows: 1
|
||||
|
||||
* - Common name
|
||||
- User-configurable?
|
||||
- L2 (non-tunneled)
|
||||
- L3 (tunneled)
|
||||
* - Provider network
|
||||
- No
|
||||
- Yes
|
||||
- No
|
||||
* - Tenant network
|
||||
- Yes
|
||||
- Yes (not common)
|
||||
- Yes (common)
|
||||
|
||||
This entire spec focuses on the *technologies* as these are what determine
|
||||
how traffic will egress from a compute node, which is the primary concern
|
||||
here.
|
||||
|
||||
Physical networks
|
||||
Physical networks, or *physnet*\s, are identified through the use of an
|
||||
arbitrary label. In the case of the Open vSwitch (OVS) ML2 driver, these
|
||||
labels are mapped to a given OVS bridge containing the physical interfaces
|
||||
using the ``[ovs] bridge_mappings`` neutron configuration option. For
|
||||
example:
|
||||
|
||||
.. code-block:: ini
|
||||
:caption: openvswitch_agent.ini
|
||||
|
||||
[ovs]
|
||||
bridge_mappings = provider:br-provider
|
||||
|
||||
This will map the *physnet* ``provider`` to an OVS bridge ``br-provider``. It
|
||||
is expected that this bridge will contain a logical interface (you can use
|
||||
bonded NICs to provide failover). A similar configuration option exists for
|
||||
the Linux Bridge ML2 driver: ``[linux_bridge] physical_interface_mappings``.
|
||||
|
||||
Tunneled networks
|
||||
Networks with a tunnel overlay, or tunneled networks, may also provide
|
||||
external network connectivity. There can be many tunneled networks but only
|
||||
one logical interface (you can use bonded NICs to provide failover) on a host
|
||||
should be handling traffic for these networks. This interface is configured
|
||||
using the ``[ovs] local_ip`` *neutron* configuration option. For example:
|
||||
|
||||
.. code-block:: ini
|
||||
:caption: openvswitch_agent.ini
|
||||
|
||||
[ovs]
|
||||
local_ip = OVERLAY_INTERFACE_IP_ADDRESS
|
||||
|
||||
This will result in all *VXLAN* or *GRE* traffic using the interface whose IP
|
||||
corresponds to ``OVERLAY_INTERFACE_IP_ADDRESS``. A similar configuration
|
||||
option exists for the Linux Bridge ML2 driver for *VXLAN* traffic: ``[vxlan]
|
||||
local_ip``. This driver does not support *GRE* traffic.
|
||||
|
||||
It is possible for both physical and tunneled networks to be used on the same
|
||||
host. Given all of this, we propose the following changes.
|
||||
|
||||
Changes
|
||||
-------
|
||||
|
||||
Configuration options
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
We propose adding a new configuration option and multiple dynamically-generated
|
||||
configuration groups.
|
||||
|
||||
* The ``[neutron] physnets`` configuration option will list all *physnets* for
|
||||
which you wish to provide NUMA affinity.
|
||||
|
||||
* The ``[neutron_tunnel]`` configuration group will allow configuration of the
|
||||
tunneled networks. Only one configuration group is required for these since
|
||||
all tunneled networks must share a logical interface. This group will
|
||||
contain a single configuration option, ``numa_nodes``, which lists the host
|
||||
NUMA node(s) to which tunneled networks are affined.
|
||||
|
||||
* Multiple ``[neutron_physnet_$PHYSNET]`` configuration groups, one per each
|
||||
``$PHYSNET`` in ``[neutron] physnets``, will allow configuration of these
|
||||
*physnets*. Each of these configuration groups will contain a single
|
||||
configuration option each, ``numa_nodes``, which lists the host NUMA node(s)
|
||||
to which networks using this *physnet* are affined.
|
||||
|
||||
The groups will all be generated dynamically, which is required as the values
|
||||
of ``$PHYSNET`` in ``[neutron_physnet_$PHYSNET]`` are arbitrary and can only be
|
||||
identified from the corresponding values in ``[neutron] physnets``.
|
||||
|
||||
This will result in configuration files like the below:
|
||||
|
||||
.. code-block:: ini
|
||||
:caption: nova.conf
|
||||
|
||||
[neutron]
|
||||
physnets = physnet0,physnet1
|
||||
|
||||
[neutron_physnet_physnet0]
|
||||
numa_nodes = 0
|
||||
|
||||
[neutron_physnet_physnet1]
|
||||
numa_nodes = 0,1
|
||||
|
||||
[neutron_tunnel]
|
||||
numa_nodes = 1
|
||||
|
||||
where:
|
||||
|
||||
``[neutron] physnets``
|
||||
A list of strings corresponding to the names of all neutron provider network
|
||||
*physnet*\s configured on this host.
|
||||
|
||||
.. note::
|
||||
|
||||
Using a combination of neutron's `hierarchical port binding`__ and
|
||||
`multiprovider network`__ features, it is possible for neutron to
|
||||
dynamically generate a network segments with a given physnet. This is
|
||||
considered out of scope for this feature.
|
||||
|
||||
``[neutron_physnet_$PHYSNET]``
|
||||
A section of opts corresponding to one of the *physnet*\s defined in
|
||||
``[neutron] physnets``. This in turn has the following keys:
|
||||
|
||||
``numa_nodes``
|
||||
A list of integers of NUMA nodes associated with this backend. It is
|
||||
defined as a list to cater for cross NUMA bonds and multipath routing. If
|
||||
this is empty, the *physnet* has no NUMA affinity assigned to it.
|
||||
|
||||
.. note::
|
||||
|
||||
A smart enough vSwitch with a active-active cross-NUMA node bond could
|
||||
use the NUMA affinity of the VM interface as an input to the hash for
|
||||
selecting the bond peer has to ensure no cross-NUMA traffic for
|
||||
inter-host traffic. Alternatively, a dumb one could have *os-vif*
|
||||
hardcode it using a OpenFlow multipath action and some other Open
|
||||
vSwitch fanciness to set the MAC affinity to NUMA local bond peer. This
|
||||
is outside of the scope of this spec.
|
||||
|
||||
``[neutron_tunnel]``
|
||||
The same as ``[neutron_physnet_$PHYSNET]`` but for the interface used by
|
||||
tunnel networks.
|
||||
|
||||
As noted previously, a host may use *physnet*\s networks, tunneled networks or
|
||||
a combination of both. As a result, not all configuration values may be
|
||||
specified on a given host.
|
||||
|
||||
This configuration will be generated by an orchestration tool at deployment
|
||||
time in the same way that general host network configuration is generated.
|
||||
This is because identifying the NUMA affinity for an arbitrary network is a
|
||||
difficult problem that grows in complexity with the design of the networks and
|
||||
VNFs. The orchestration tool is responsible for configuring how physical NICs
|
||||
are used by the various neutron networks and with only a little extra work can
|
||||
extend this to include NUMA affinity (for example, by combining information
|
||||
from tools like :command:`ethtool` with information from *sysfs*).
|
||||
|
||||
NUMA affinity will be provided for all networks with a *physnet* and a defined
|
||||
``[neutron_physnet_$PHYSNET]`` group and for all tunneled networks, assuming
|
||||
``[neutron_tunnel]`` is defined. This will be stored as part of a host's
|
||||
``NUMACell`` object. If a given network is not defined in any such option, no
|
||||
NUMA affinity will be provided. As with other devices that provide NUMA
|
||||
affinity, namely PCI or SR-IOV [10]_ devices, attempting to boot an instance
|
||||
may fail in a number of cases. These are described later.
|
||||
|
||||
__ https://blueprints.launchpad.net/neutron/+spec/ml2-hierarchical-port-binding
|
||||
__ https://blueprints.launchpad.net/neutron/+spec/provider-network-partial-specs
|
||||
|
||||
Network API Client
|
||||
~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The network API client in nova currently provides a method,
|
||||
``create_pci_requests_for_sriov_ports`` [11]_, which retrieves information
|
||||
about *physnets* and VNIC types of each port requested when booting an instance
|
||||
for the purpose of creating PCI requests for SRIOV ports. This will be made
|
||||
more generic and extended to get information about the tunneled status of any
|
||||
requested networks. This information will be stored (but not persisted) in a
|
||||
new object, ``InstanceNUMANetworks``, for later consumption.
|
||||
|
||||
.. note::
|
||||
|
||||
As with the `existing SR-IOV feature`__, this will only handle the case
|
||||
where an entire network, as opposed to a segment of the network, is
|
||||
associated with the physnet.
|
||||
|
||||
__ https://github.com/openstack/nova/blob/881103c9b/nova/network/neutronv2/api.py#L1537
|
||||
|
||||
Scheduling
|
||||
~~~~~~~~~~
|
||||
|
||||
In addition to the configuration change, we will need to start including the
|
||||
list of requested *phynets* and *tunneled networks*, stored in the new
|
||||
``InstanceNUMANetworks`` object, as a field of the ``RequestSpec`` object. This
|
||||
field will not be persisted in the database. We require this information so we
|
||||
can use it to build the NUMA topology of the instance on the host as part of
|
||||
scheduling but it does not need to be stored after this. We also need to extend
|
||||
the ``limits`` dictionary returned by the ``NUMATopologyFilter`` to include
|
||||
information about the networks. This is necessary so we have something to
|
||||
reference during the *claim* stage on the compute. In both cases, the cached
|
||||
information will need to be updated in the event of a move operation.
|
||||
|
||||
Virtualization driver
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Only the libvirt driver currently supports the full breadth of NUMA affinity
|
||||
features required for this feature. While other drivers, notably Hyper-V, do
|
||||
support some NUMA features, these are related to guest NUMA topologies and not
|
||||
placement of vCPU processes across host NUMA nodes. The NUMA fitting code,
|
||||
found in ``numa_fit_instance_to_host``, will be updated to consume a new
|
||||
``InstanceNUMANetworks`` object and use this to determine which host NUMA nodes
|
||||
to use. The ``InstanceNUMANetworks`` object will be built from information in
|
||||
the ``RequestSpec`` objects or scheduler limits and passed in by the caller of
|
||||
this function.
|
||||
|
||||
Potential issues
|
||||
----------------
|
||||
|
||||
As noted above, this is a rather difficult issue to solve sanely and, as a
|
||||
result, there are a number of situations that need special workarounds. The
|
||||
first arises where physical NICs from different NUMA nodes are bonded. This
|
||||
will not break the world but is not intended to have anything but poor
|
||||
performance. This exact situation can arise in SR-IOV too and generally occurs
|
||||
because:
|
||||
|
||||
- The operator has misconfigured something
|
||||
- The operator does not care about optimal performance
|
||||
- The operator wants to provide resiliency by spreading work across NICs and
|
||||
cannot or will not use two NICs from the same NUMA node
|
||||
|
||||
Given that we can't determine if this was intentional or not, we have defined
|
||||
``numa_nodes`` as a list rather than a single integer. This will allow us to
|
||||
capture the combined NUMA affinity of the bonded NICs.
|
||||
|
||||
The second situation is guests with complex, multi-NIC configurations. Most
|
||||
VNFs utilize multiple interfaces, some of which will be used for VM management
|
||||
interfaces (SSH, logging, SNMP, ...) while the remainder will be used for
|
||||
actual data plane interfaces. NUMA affinity doesn't matter for the former so we
|
||||
can ignore these, however, if the latter ports have different affinities, it
|
||||
can be impossible to determine a natural NUMA affinity. This can be seen below:
|
||||
|
||||
.. figure:: /_images/numa-aware-vswitches-5.png
|
||||
:width: 90%
|
||||
|
||||
This exact situation occurs with PCI and SR-IOV devices and here, as with those
|
||||
devices, we expect users to define a multi-node guest topology or to avoid
|
||||
specifying NUMA affinity for the non-data plane interfaces.
|
||||
|
||||
The third situation is VM to VM traffic. Current NFV deployments do not
|
||||
generally care about VM to VM traffic as it's highly unlikely that two related
|
||||
VNFs would ever be intentionally collocated on a given host. As such, VM to VM
|
||||
traffic is considered out of scope for this spec.
|
||||
|
||||
The fourth and final situation is interfaces that are attached after creating
|
||||
the instance. Interfaces for which NUMA affinity is required must be requested
|
||||
when creating instances and any interfaces attached after this will not have
|
||||
NUMA affinity applied to them. This is required to limit the scope of this
|
||||
feature and will be resolved in a future spec, however, a resize operation or
|
||||
similar can be used after attaching new interfaces to gain NUMA affinity for
|
||||
these interfaces.
|
||||
|
||||
Alternatives
|
||||
------------
|
||||
|
||||
There are multiple possible solutions to this issue of various levels of
|
||||
complexity.
|
||||
|
||||
We could store the static backend-NUMA mapping in neutron instead and pass this
|
||||
over the wire as part of the VIF request. As neutron is responsible for all
|
||||
things network'y, storing this information in nova might appear to break the
|
||||
separation of concerns between the two services. However, this is only
|
||||
partially true. While neutron is responsible for creating network elements such
|
||||
as ports and bridges, it is nova that is responsible for wiring them up to
|
||||
instances. This does not get nova into the business of actually creating the
|
||||
underlying network elements, but rather it will now store additional metadata
|
||||
about said elements. Moving this configuration into neutron would complicate
|
||||
matters for little to no gain.
|
||||
|
||||
An even more elaborate alternative would be dynamically generate this
|
||||
information in neutron, rather than hardcoding it in either nova or neutron.
|
||||
This information could be exposed via a new extension or similar. This would
|
||||
appear to incur the least amount of effort on a deployer's side and would seem
|
||||
like the most intelligent thing to do. However, this is not perfect either.
|
||||
Implementing this functionality would require changes to nearly every backend
|
||||
in neutron and may not even be possible for some backends and some particularly
|
||||
complex configurations. As noted previously, we have access to information on
|
||||
the overall network design at deployment time and discarding that in favour of
|
||||
dynamic generation introduces unnecessary magic to the formula.
|
||||
|
||||
We could go all in on placement from a neutron side and start storing
|
||||
information about the various backends from neutron. Nova would then be able to
|
||||
use this information in order to make its scheduling decisions. This is
|
||||
technically the best solution as it solves both this issue and a number of
|
||||
other issues, such as bandwidth-aware scheduling and discovery of the types of
|
||||
networks available on a compute node _before_ landing on that node. However, we
|
||||
don't currently have a clear story for modelling NUMA resources in placement
|
||||
[12]_. Given the tenant dataplane performance issues being faced right now,
|
||||
this seems untenable. However, that's not to say we can't migrate some of this
|
||||
information to placement in the future. This was discussed during the Rocky PTG
|
||||
in Dublin [13]_.
|
||||
|
||||
OpenDaylight (ODL) uses per host configuration stored in OVS (like bridge
|
||||
mappings), which are then read by ODL and populated into Neutron DB as pseudo
|
||||
agents. We could store the *NUMA:physnet* affinity per network on a per-host
|
||||
basis in OVS, eventually propagating this info to the VIF request for nova.
|
||||
However, this isn't feasible for tenant networks as the NUMA topology of the
|
||||
host is not visible to a tenant. In addition, this relies on specific features
|
||||
of the network backend which might not be available in other backends.
|
||||
|
||||
Finally, and this is the nuclear option, we could simply embrace the fact that
|
||||
scheduling decisions in the NFV space are tough to do automatically and it
|
||||
might be better to delegate this to another system. To this end, we could
|
||||
simply expose a "deploy on this **host** NUMA node" knob and let users at it.
|
||||
This would simplify our lives and satisfy the requests of these users, but it
|
||||
is distinctly uncloudy and unlikely to gain any traction.
|
||||
|
||||
Data model impact
|
||||
-----------------
|
||||
|
||||
A new object, ``NUMANetworkInfo``, will be added to store information about
|
||||
networks associated with a host NUMA node. This will be mapped to a parent
|
||||
``NUMACell`` object using a ``network_info`` field and will be used to compare
|
||||
against the requested networks for one or more instances during scheduling and
|
||||
claiming.
|
||||
|
||||
A new object, ``InstanceNUMANetworks``, will be added to store information
|
||||
about whether the networks requested for or attached to an instance were
|
||||
*physnets* or *tunneled networks*. They will be populated by a more generic
|
||||
version of the ``create_pci_requests_for_sriov_ports`` function. They will not
|
||||
be persisted and is merely stored as a way to get this information from the API
|
||||
to the scheduler for use in filtering.
|
||||
|
||||
REST API impact
|
||||
---------------
|
||||
|
||||
None.
|
||||
|
||||
Security impact
|
||||
---------------
|
||||
|
||||
None.
|
||||
|
||||
Notifications impact
|
||||
--------------------
|
||||
|
||||
None.
|
||||
|
||||
Other end user impact
|
||||
---------------------
|
||||
|
||||
None.
|
||||
|
||||
Performance Impact
|
||||
------------------
|
||||
|
||||
There will be a negligible increase in the time taken to schedule an instance
|
||||
on account of the additional NUMA affinity checks. However, network performance
|
||||
of some vSwitch solutions (OVS-DPDK, for example) will increase by up to 100%.
|
||||
|
||||
Other deployer impact
|
||||
---------------------
|
||||
|
||||
Deployment tooling will need to be enhanced to configure the new configuration
|
||||
option at deployment time.
|
||||
|
||||
Developer impact
|
||||
----------------
|
||||
|
||||
This change will require changes to the scheduler but only the libvirt driver
|
||||
will provide the information necessary to properly schedule these requests.
|
||||
Additional drivers do not currently provide sufficient awareness of host NUMA
|
||||
information for this change to be incorporated in a meaningful manner. If this
|
||||
changes in the future, the drivers will need to be extended to consume the
|
||||
configuration option and request spec attributes.
|
||||
|
||||
Upgrade impact
|
||||
--------------
|
||||
|
||||
The new configuration options will need to be created for each *nova-compute*
|
||||
services ``nova.conf`` file. In addition, any database migrations will need to
|
||||
be run.
|
||||
|
||||
|
||||
Implementation
|
||||
==============
|
||||
|
||||
Assignee(s)
|
||||
-----------
|
||||
|
||||
Primary assignee:
|
||||
stephenfinucane
|
||||
|
||||
Other contributors:
|
||||
sean-k-mooney
|
||||
|
||||
Work Items
|
||||
----------
|
||||
|
||||
#. Add support for the new configuration option and dynamic configuration
|
||||
groups.
|
||||
|
||||
#. Create a ``NUMANetworkInfo`` object. This will be used to store the
|
||||
NUMA-network configuration provided in ``nova.conf``, namely, if any
|
||||
*physnets* or *tunneled networks* are affinitized to this cell.
|
||||
|
||||
#. Add a ``network_info`` field to the ``NUMACell`` object, which will include
|
||||
network information about the host node in the form of a ``NUMANetworkInfo``
|
||||
object. This is required so *nova-scheduler* and *nova-conductor* can
|
||||
access this information during scheduling and claiming, respectively.
|
||||
|
||||
#. Create a ``InstanceNUMANetworks`` object. This will be used to store the
|
||||
combined *physnets* or *tunneled* attributes of the networks requested for
|
||||
the instance.
|
||||
|
||||
#. Make ``create_pci_requests_for_sriov_ports`` more generic. This can be used
|
||||
to fetch most of the information we need to populate the new
|
||||
``InstanceNUMANetworks`` object.
|
||||
|
||||
#. Add a ``numa_networks`` field to the ``RequestSpec`` object, which will
|
||||
be the ``InstanceNUMANetworks`` object generated from the call to
|
||||
``create_pci_requests_for_sriov_ports`` by the API service. This information
|
||||
will be used by the ``NUMATopologyFilter`` to filter out hosts that could
|
||||
not satisfy the request. This field will not be persisted as it is only
|
||||
needed by the scheduler when scheduling new instances.
|
||||
|
||||
#. Modify the ``numa_fit_instance_to_host`` function to accept a new
|
||||
``numa_networks`` argument, which will be an instance of
|
||||
``InstanceNUMANetworks``, and consider these when building NUMA topologies.
|
||||
|
||||
#. Modify the ``NUMATopologyFilter`` to populate a ``numa_networks`` field
|
||||
for the ``limits`` dictionary. This will be populated with an instance of
|
||||
``InstanceNUMANetworks`` built using the value of
|
||||
``RequestSpec.numa_networks``. Pass the ``InstanceNUMANetworks`` object to
|
||||
``numa_fit_instance_to_host``.
|
||||
|
||||
#. Modify the serialized models stored in ``Instance.info_cache.network_info``
|
||||
to include something akin to the ``physnet`` and ``tunneled`` fields for
|
||||
each network. This is required for claims during any move operation.
|
||||
|
||||
#. Modify *nova-conductor* to build a ``InstanceNUMANetworks`` object from the
|
||||
``Instance.info_cache.network_info`` field, which can be used to populate
|
||||
the ``RequestSpec`` object for any move operation.
|
||||
|
||||
#. Modify how claims are done on the compute to account for network info from
|
||||
the ``limits`` (passed down from the scheduler) when building the
|
||||
instance's NUMA topology.
|
||||
|
||||
|
||||
Dependencies
|
||||
============
|
||||
|
||||
None. `numa-aware-live-migration`_ is required to support live migration of
|
||||
instances with any CPU pinning and NUMA topology functionality enable. However,
|
||||
given that live migration is currently broken for **all** NUMA use cases, the
|
||||
lack of live migration support for this particular NUMA'y use case should not
|
||||
be considered a blocker.
|
||||
|
||||
.. _numa-aware-live-migration: https://blueprints.launchpad.net/nova/+spec/numa-aware-live-migration
|
||||
|
||||
|
||||
Testing
|
||||
=======
|
||||
|
||||
Like anything else that utilizes real hardware, this cannot be tested in the
|
||||
upstream CI. Instead, we will need to rely on unit tests, functional tests
|
||||
(with hardware mocked out), and downstream or third-party CIs to provide
|
||||
testing.
|
||||
|
||||
|
||||
Documentation Impact
|
||||
====================
|
||||
|
||||
The feature will need to be documented in full, though we do get the
|
||||
configuration documentation for free (thanks ``oslo_config.sphinxext``).
|
||||
|
||||
|
||||
References
|
||||
==========
|
||||
|
||||
.. [1] https://www.slideshare.net/LF_OpenvSwitch/lfovs17ovsdpdk-for-nfv-go-live-feedback/12
|
||||
.. [2] http://docs.openvswitch.org/en/latest/topics/dpdk/vhost-user/
|
||||
.. [3] http://docs.openvswitch.org/en/latest/topics/dpdk/phy/
|
||||
.. [4] http://docs.openvswitch.org/en/latest/topics/dpdk/pmd/
|
||||
.. [5] https://software.intel.com/en-us/articles/vhost-user-numa-awareness-in-open-vswitch-with-dpdk
|
||||
.. [6] https://docs.openstack.org/neutron/queens/admin/deploy-lb-provider.html
|
||||
.. [7] https://docs.openstack.org/neutron/queens/admin/deploy-ovs-provider.html
|
||||
.. [8] https://docs.openstack.org/neutron/queens/admin/deploy-lb-selfservice.html
|
||||
.. [9] https://docs.openstack.org/neutron/queens/admin/deploy-ovs-selfservice.html
|
||||
.. [10] https://docs.openstack.org/neutron/queens/admin/config-sriov.html
|
||||
.. [11] https://github.com/openstack/nova/blob/17.0.0/nova/network/neutronv2/api.py#L1556
|
||||
.. [12] https://review.openstack.org/#/c/552924/
|
||||
.. [13] https://etherpad.openstack.org/p/nova-ptg-rocky
|
||||
|
||||
|
||||
History
|
||||
=======
|
||||
|
||||
.. list-table:: Revisions
|
||||
:header-rows: 1
|
||||
|
||||
* - Release Name
|
||||
- Description
|
||||
* - Rocky
|
||||
- Introduced
|
Loading…
Reference in New Issue