cinder/doc/source/configuration/block-storage/fc-zoning.rst

4.0 KiB

Fibre Channel Zone Manager

The Fibre Channel Zone Manager allows FC SAN Zone/Access control management in conjunction with Fibre Channel block storage. The configuration of Fibre Channel Zone Manager and various zone drivers are described in this section.

Configure Block Storage to use Fibre Channel Zone Manager

If Block Storage is configured to use a Fibre Channel volume driver that supports Zone Manager, update cinder.conf to add the following configuration options to enable Fibre Channel Zone Manager.

Make the following changes in the /etc/cinder/cinder.conf file.

To use different Fibre Channel Zone Drivers, use the parameters described in this section.

Note

When multi backend configuration is used, provide the zoning_mode configuration option as part of the volume driver configuration where volume_driver option is specified.

Note

Default value of zoning_mode is None and this needs to be changed to fabric to allow fabric zoning.

Note

zoning_policy can be configured as initiator-target or initiator

Brocade Fibre Channel Zone Driver

Brocade Fibre Channel Zone Driver performs zoning operations through HTTP, HTTPS, or SSH.

Set the following options in the cinder.conf configuration file.

Configure SAN fabric parameters in the form of fabric groups as described in the example below:

Note

Define a fabric group for each fabric using the fabric names used in fc_fabric_names configuration option as group name.

Note

To define a fabric group for a switch which has Virtual Fabrics enabled, include the fc_virtual_fabric_id configuration option and fc_southbound_protocol configuration option set to HTTP or HTTPS in the fabric group. Zoning on VF enabled fabric using SSH southbound protocol is not supported.

System requirements

Brocade Fibre Channel Zone Driver requires firmware version FOS v6.4 or higher.

As a best practice for zone management, use a user account with zoneadmin role. Users with admin role (including the default admin user account) are limited to a maximum of two concurrent SSH sessions.

For information about how to manage Brocade Fibre Channel switches, see the Brocade Fabric OS user documentation.

Cisco Fibre Channel Zone Driver

Cisco Fibre Channel Zone Driver automates the zoning operations through SSH. Configure Cisco Zone Driver, Cisco Southbound connector, FC SAN lookup service and Fabric name.

Set the following options in the cinder.conf configuration file.

[fc-zone-manager]
zone_driver = cinder.zonemanager.drivers.cisco.cisco_fc_zone_driver.CiscoFCZoneDriver
fc_san_lookup_service = cinder.zonemanager.drivers.cisco.cisco_fc_san_lookup_service.CiscoFCSanLookupService
fc_fabric_names = CISCO_FABRIC_EXAMPLE
cisco_sb_connector = cinder.zonemanager.drivers.cisco.cisco_fc_zone_client_cli.CiscoFCZoneClientCLI

Configure SAN fabric parameters in the form of fabric groups as described in the example below:

Note

Define a fabric group for each fabric using the fabric names used in fc_fabric_names configuration option as group name.

The Cisco Fibre Channel Zone Driver supports basic and enhanced zoning modes.The zoning VSAN must exist with an active zone set name which is same as the fc_fabric_names option.

System requirements

Cisco MDS 9000 Family Switches.

Cisco MDS NX-OS Release 6.2(9) or later.

For information about how to manage Cisco Fibre Channel switches, see the Cisco MDS 9000 user documentation.