1.3 KiB
1.3 KiB
VLAN Segmentation
Depending on the number of NICs you have in your node servers, you can use the following examples to plan your NIC assignment:
3 NIC deployment
- eth0 - untagged port for Administrative network
- eth1 (br-eth1) - port for networks: Public/Floating, Management, Storage
- eth2 (br-eth2) - port for Private network (where the number of VLANs depends on the number of tenant networks with a continuous range)
4 NIC deployment
- eth0 - port for Administrative network
- eth1 (br-eth1) - port for networks: Public/Floating, Management
- eth2 (br-eth2) - port for Private network, with defined VLAN range IDs
- eth3 (br-eth1) - port for Storage network
Routing recommendations
- Use the default routing via a router in the Public network
- Use the the management network to access to your management infrastructure (L3 connectivity if necessary)
- The administrative network or only the Fuel server (via dedicated NIC) should have Internet access
- The Storage and Private network (VLANs) should be configured without access to other networks (no L3 connectivity)