Dell EMC VNX driver
|
|
===================
|
|
|
|
The EMC Shared File Systems service driver framework (EMCShareDriver)
|
|
utilizes the EMC storage products to provide the shared file systems to
|
|
OpenStack. The EMC driver is a plug-in based driver which is designed to
|
|
use different plug-ins to manage different EMC storage products.
|
|
|
|
The VNX plug-in is the plug-in which manages the VNX to provide shared
|
|
filesystems. The EMC driver framework with the VNX plug-in is referred
|
|
to as the VNX driver in this document.
|
|
|
|
This driver performs the operations on VNX by XMLAPI and the file
|
|
command line. Each back end manages one Data Mover of VNX. Multiple
|
|
Shared File Systems service back ends need to be configured to manage
|
|
multiple Data Movers.
|
|
|
|
.. note::
|
|
|
|
Dell EMC VNX driver has been deprecated and will be removed in a future
|
|
release
|
|
|
|
Requirements
|
|
~~~~~~~~~~~~
|
|
|
|
- VNX OE for File version 7.1 or higher
|
|
|
|
- VNX Unified, File only, or Gateway system with a single storage back
|
|
end
|
|
|
|
- The following licenses should be activated on VNX for File:
|
|
|
|
- CIFS
|
|
|
|
- NFS
|
|
|
|
- SnapSure (for snapshot)
|
|
|
|
- ReplicationV2 (for create share from snapshot)
|
|
|
|
Supported shared filesystems and operations
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The driver supports CIFS and NFS shares.
|
|
|
|
The following operations are supported:
|
|
|
|
- Create a share.
|
|
|
|
- Delete a share.
|
|
|
|
- Allow share access.
|
|
|
|
Note the following limitations:
|
|
|
|
- Only IP access type is supported for NFS.
|
|
- Only user access type is supported for CIFS.
|
|
|
|
- Deny share access.
|
|
|
|
- Create a snapshot.
|
|
|
|
- Delete a snapshot.
|
|
|
|
- Create a share from a snapshot.
|
|
|
|
While the generic driver creates shared filesystems based on cinder
|
|
volumes attached to nova VMs, the VNX driver performs similar operations
|
|
using the Data Movers on the array.
|
|
|
|
Pre-configurations on VNX
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
#. Enable unicode on Data Mover.
|
|
|
|
The VNX driver requires that the unicode is enabled on Data Mover.
|
|
|
|
.. warning::
|
|
|
|
After enabling Unicode, you cannot disable it. If there are some
|
|
filesystems created before Unicode is enabled on the VNX,
|
|
consult the storage administrator before enabling Unicode.
|
|
|
|
To check the Unicode status on Data Mover, use the following VNX File
|
|
command on the VNX control station::
|
|
|
|
server_cifs <mover_name> | head
|
|
# mover_name = <name of the Data Mover>
|
|
|
|
Check the value of I18N mode field. UNICODE mode is shown as
|
|
``I18N mode = UNICODE``.
|
|
|
|
To enable the Unicode for Data Mover::
|
|
|
|
uc_config -on -mover <mover_name>
|
|
# mover_name = <name of the Data Mover>
|
|
|
|
Refer to the document Using International Character Sets on VNX for
|
|
File on `EMC support site <http://support.emc.com>`_ for more
|
|
information.
|
|
|
|
#. Enable CIFS service on Data Mover.
|
|
|
|
Ensure the CIFS service is enabled on the Data Mover which is going
|
|
to be managed by VNX driver.
|
|
|
|
To start the CIFS service, use the following command::
|
|
|
|
server_setup <mover_name> -Protocol cifs -option start [=<n>]
|
|
# mover_name = <name of the Data Mover>
|
|
# n = <number of threads for CIFS users>
|
|
|
|
.. note::
|
|
|
|
If there is 1 GB of memory on the Data Mover, the default is 96
|
|
threads; however, if there is over 1 GB of memory, the default
|
|
number of threads is 256.
|
|
|
|
To check the CIFS service status, use this command::
|
|
|
|
server_cifs <mover_name> | head
|
|
# mover_name = <name of the Data Mover>
|
|
|
|
The command output will show the number of CIFS threads started.
|
|
|
|
#. NTP settings on Data Mover.
|
|
|
|
VNX driver only supports CIFS share creation with share network
|
|
which has an Active Directory security-service associated.
|
|
|
|
Creating CIFS share requires that the time on the Data Mover is in
|
|
sync with the Active Directory domain so that the CIFS server can
|
|
join the domain. Otherwise, the domain join will fail when creating
|
|
share with this security service. There is a limitation that the
|
|
time of the domains used by security-services even for different
|
|
tenants and different share networks should be in sync. Time
|
|
difference should be less than 10 minutes.
|
|
|
|
It is recommended to set the NTP server to the same public NTP
|
|
server on both the Data Mover and domains used in security services
|
|
to ensure the time is in sync everywhere.
|
|
|
|
Check the date and time on Data Mover::
|
|
|
|
server_date <mover_name>
|
|
# mover_name = <name of the Data Mover>
|
|
|
|
Set the NTP server for Data Mover::
|
|
|
|
server_date <mover_name> timesvc start ntp <host> [<host> ...]
|
|
# mover_name = <name of the Data Mover>
|
|
# host = <IP address of the time server host>
|
|
|
|
.. note::
|
|
|
|
The host must be running the NTP protocol. Only 4 host entries
|
|
are allowed.
|
|
|
|
#. Configure User Mapping on the Data Mover.
|
|
|
|
Before creating CIFS share using VNX driver, you must select a
|
|
method of mapping Windows SIDs to UIDs and GIDs. EMC recommends
|
|
using usermapper in single protocol (CIFS) environment which is
|
|
enabled on VNX by default.
|
|
|
|
To check usermapper status, use this command syntax::
|
|
|
|
server_usermapper <movername>
|
|
# movername = <name of the Data Mover>
|
|
|
|
If usermapper is not started, the following command can be used
|
|
to start the usermapper::
|
|
|
|
server_usermapper <movername> -enable
|
|
# movername = <name of the Data Mover>
|
|
|
|
For a multiple protocol environment, refer to Configuring VNX User
|
|
Mapping on `EMC support site <http://support.emc.com>`_ for
|
|
additional information.
|
|
|
|
#. Network Connection.
|
|
|
|
Find the network devices (physical port on NIC) of Data Mover that
|
|
has access to the share network.
|
|
|
|
Go to :guilabel:`Unisphere` to check the device list:
|
|
:menuselection:`Settings > Network > Settings for File (Unified system
|
|
only) > Device`.
|
|
|
|
|
|
Back-end configurations
|
|
~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following parameters need to be configured in the
|
|
``/etc/manila/manila.conf`` file for the VNX driver:
|
|
|
|
.. code-block:: ini
|
|
|
|
emc_share_backend = vnx
|
|
emc_nas_server = <IP address>
|
|
emc_nas_password = <password>
|
|
emc_nas_login = <user>
|
|
vnx_server_container = <Data Mover name>
|
|
vnx_share_data_pools = <Comma separated pool names>
|
|
share_driver = manila.share.drivers.emc.driver.EMCShareDriver
|
|
vnx_ethernet_ports = <Comma separated ports list>
|
|
|
|
- `emc_share_backend`
|
|
The plug-in name. Set it to ``vnx`` for the VNX driver.
|
|
|
|
- `emc_nas_server`
|
|
The control station IP address of the VNX system to be managed.
|
|
|
|
- `emc_nas_password` and `emc_nas_login`
|
|
The fields that are used to provide credentials to the
|
|
VNX system. Only local users of VNX File is supported.
|
|
|
|
- `vnx_server_container`
|
|
Name of the Data Mover to serve the share service.
|
|
|
|
- `vnx_share_data_pools`
|
|
Comma separated list specifying the name of the pools to be used
|
|
by this back end. Do not set this option if all storage pools
|
|
on the system can be used.
|
|
Wild card character is supported.
|
|
|
|
Examples: pool_1, pool_*, *
|
|
|
|
- `vnx_ethernet_ports`
|
|
Comma separated list specifying the ports (devices) of Data Mover
|
|
that can be used for share server interface. Do not set this
|
|
option if all ports on the Data Mover can be used.
|
|
Wild card character is supported.
|
|
|
|
Examples: spa_eth1, spa_*, *
|
|
|
|
|
|
Restart of the ``manila-share`` service is needed for the configuration
|
|
changes to take effect.
|
|
|
|
|
|
Restrictions
|
|
~~~~~~~~~~~~
|
|
|
|
The VNX driver has the following restrictions:
|
|
|
|
- Only IP access type is supported for NFS.
|
|
|
|
- Only user access type is supported for CIFS.
|
|
|
|
- Only FLAT network and VLAN network are supported.
|
|
|
|
- VLAN network is supported with limitations. The neutron subnets in
|
|
different VLANs that are used to create share networks cannot have
|
|
overlapped address spaces. Otherwise, VNX may have a problem to
|
|
communicate with the hosts in the VLANs. To create shares for
|
|
different VLANs with same subnet address, use different Data Movers.
|
|
|
|
- The ``Active Directory`` security service is the only supported
|
|
security service type and it is required to create CIFS shares.
|
|
|
|
- Only one security service can be configured for each share network.
|
|
|
|
- Active Directory domain name of the 'active\_directory' security
|
|
service should be unique even for different tenants.
|
|
|
|
- The time on Data Mover and the Active Directory domains used in
|
|
security services should be in sync (time difference should be less
|
|
than 10 minutes). It is recommended to use same NTP server on both
|
|
the Data Mover and Active Directory domains.
|
|
|
|
- On VNX the snapshot is stored in the SavVols. VNX system allows the
|
|
space used by SavVol to be created and extended until the sum of the
|
|
space consumed by all SavVols on the system exceeds the default 20%
|
|
of the total space available on the system. If the 20% threshold
|
|
value is reached, an alert will be generated on VNX. Continuing to
|
|
create snapshot will cause the old snapshot to be inactivated (and
|
|
the snapshot data to be abandoned). The limit percentage value can be
|
|
changed manually by storage administrator based on the storage needs.
|
|
Administrator is recommended to configure the notification on the
|
|
SavVol usage. Refer to Using VNX SnapSure document on `EMC support
|
|
site <http://support.emc.com>`_ for more information.
|
|
|
|
- VNX has limitations on the overall numbers of Virtual Data Movers,
|
|
filesystems, shares, checkpoints, etc. Virtual Data Mover(VDM) is
|
|
created by the VNX driver on the VNX to serve as the Shared File
|
|
Systems service share server. Similarly, filesystem is created,
|
|
mounted, and exported from the VDM over CIFS or NFS protocol to serve
|
|
as the Shared File Systems service share. The VNX checkpoint serves
|
|
as the Shared File Systems service share snapshot. Refer to the NAS
|
|
Support Matrix document on `EMC support
|
|
site <http://support.emc.com>`_ for the limitations and configure the
|
|
quotas accordingly.
|
|
|
|
Driver options
|
|
~~~~~~~~~~~~~~
|
|
|
|
Configuration options specific to this driver:
|
|
|
|
.. include:: ../../tables/manila-vnx.inc
|