Guide to the EMC VNX Plugin for Fuel
EMC VNX plugin for Fuel extends Mirantis OpenStack functionality by adding support for EMC VNX arrays in Cinder using iSCSI protocol. It replaces Cinder LVM driver which is the default volume backend that uses local volumes managed by LVM. Enabling EMC VNX plugin in Mirantis OpenStack means that all Cinder services are run on Controller nodes.
Requirements
Requirement | Version/Comment |
---|---|
Fuel | 8.0 |
EMC VNX array |
|
Limitations
- Since only one storage network is available in Fuel 8.x on OpenStack nodes, multipath will bind all storage paths from EMC on one network interface. In case this NIC fails, the communication with storage is lost.
- Fibre Channel driver is not supported.
- EMC VNX plugin cannot be used together with cinder role and/or options 'Cinder LVM over iSCSI for volumes', 'Ceph RBD for volumes (Cinder)'.
Compatible monitoring plugins
- zabbix_monitoring-2.5-2.5.0-1.noarch.rpm
- zabbix_snmptrapd-1.0-1.0.1-1.noarch.rpm
- zabbix_monitoring_extreme_networks-1.0-1.0.1-1.noarch.rpm
- zabbix_monitoring_emc-1.0-1.0.1-1.noarch.rpm