Define idrac Hardware Type Support of Redfish Interfaces
https://storyboard.openstack.org/#!/story/2004592
Operators need the ability to configure Ironic to use Redfish to manage Dell EMC bare metal servers, and be assured it:
- offers a means of incrementally increasing the use of Redfish as Ironic's support, the standard, and Dell EMC service implementations evolve,
- delivers management protocol choice among those supported by Dell EMC --Intelligent Platform Management Interface (IPMI), Redfish, and Web Services Management (WS-Man),
- provides all the
idrac
hardware type functionality they have relied on, - works and will continue to,
- is supported by the vendor and community, and
- can offer Dell EMC value added.
This specification suggests the idrac
hardware type
provides that.
Problem description
Use cases
Expanding on what the introductory paragraph describes above, several use cases can be envisioned. While this specification enables them, it may turn out only some will find practical use among operators. That could be driven by many factors, including an existing versus greenfield deployment, operator comfort level with Redfish versus WS-Man, maturity of the protocol implementations, availability of needed functionality across Redfish and WS-Man, requirement for vendor value added, operational plans and schedules, among others.
Here they are. Note that except for the first two, they can be used in combination to configure a single Dell EMC bare metal server.
- An Admin User has a Dell EMC bare metal server and uses only WS-Man to manage it.
- An Admin User has a Dell EMC bare metal server and uses only Redfish to manage it.
- An Admin User has a Dell EMC bare metal server and uses both Redfish and WS-Man to manage it. When both offer the needed functionality, either is used.
- An Admin User has a Dell EMC bare metal server and uses both Redfish and WS-Man to manage it. Ironic's ability to manage the server is maximized.
- An Admin User has a Dell EMC bare metal server and uses both Redfish and WS-Man to manage it. Vendor value added, which is available from only one or both, is used.
Proposed change
Background
The idrac
hardware type is the Ironic driver intended
for use with Dell EMC bare metal servers equipped with an integrated
Dell Remote Access Controller (iDRAC) baseboard management controller
(BMC). To date, all the out-of-band (OOB) management protocol-dependent
interface implementations idrac
has supported use the
WS-Man protocol to interact with the iDRAC. Those implement the
inspect
, management
, power
,
raid
, and vendor
hardware interfaces. Like the
hardware type, they are named idrac
. They rely on python-dracclient's
WS-Man client.
Operators also have the option to use the generic, vendor-independent
redfish
hardware type with Dell EMC bare metal servers that
have an iDRAC that supports the Redfish protocol. redfish
's
supported OOB protocol-dependent interface implementations use the
Redfish protocol to interact with the BMC. Those implement the
bios
, inspect
, management
, and
power
hardware interfaces. Again, like the hardware type,
they are named redfish
. They rely on sushy's Redfish
client. Importantly, while some of those work with the iDRAC, including
management
and power
, not all of them do.
The redfish
hardware type enables managing servers
compliant with the Redfish protocol. However, it is relatively new, and
the protocol standard has been evolving, along with its implementations
by hardware vendors such as Dell EMC. As is common among standards,
there is a difference between compliance and interoperability. For
example, the Redfish bios
interface implementation has not
worked with the iDRAC because of client and server protocol
implementation incompatibility.
While there is much functional overlap between the interface
implementations supported by the idrac
and
redfish
hardware types, it is not complete. Only
idrac
supports a raid
interface implementation
and only redfish
supports bios
. Also, the
optional hardware interface functionality available in the
idrac
and redfish
interface implementations
can differ. For example, while the redfish
implementation
of the management
hardware interface first introduced
optional boot mode functionality, idrac
does not offer
that, yet. Therefore, those two hardware types are not perfect
substitutes for one another.
Dell EMC wants to be able to offer its customers vendor value added as supported by the Redfish standard, like it has done through WS-Man. That benefits operators by making available features and functionality that has not yet been standardized. Dell EMC can be more responsive to its customers' needs and differentiate itself in the market.
Goal
With this specification, we are going to achieve the goal of promoting and accelerating the adoption of Redfish by operators with Dell EMC bare metal servers.
Non-goals
The following is considered outside the scope of this specification:
Support a node configuration with a mix of Redfish and WS-Man
management
andpower
interface implementations. The legacyidrac
implementations of themanagement
andpower
hardware interfaces interact to set the boot device. It is not clear there is a compelling need to accommodate that in a mixed Redfish and WS-Man configuration.The following TripleO command can be used to register and configure nodes for their deployment with Ironic:
openstack overcloud node import instackenv.json
See the TripleO register nodes documentation. It sets properties in a node's
driver_info
field which are required by its driver. Presently, when the node's driver isidrac
, those are the properties --drac_address
,drac_username
, anddrac_password
-- needed by the WS-Man interface implementationsidrac
has supported. See the iDRAC driver documentation.The Redfish interface implementations need similar, but different, properties in the
driver_info
field, includingredfish_address
,redfish_system_id
,redfish_username
, andredfish_password
. See the Redfish driver documentation.Changing that TripleO command to set both the Redfish and WS-Man properties in a node's
driver_info
field when itsdriver
isidrac
is beyond the scope of this specification. That will be addressed by a TripleO project blueprint.Define
idrac
hardware type support of IPMI interface implementations. That could be done as a follow-on to this.
Solution
This specification proposes to solve the problem it describes by
changing the idrac
hardware type. Since the Ironic Driver
composition reform, we have been allowed to have "one vendor driver
with options configurable per node instead of many drivers for every
vendor."1 The reform's goals include 2:
* Make vendors in charge of defining a set of supported interface
implementations in priority order
* Allow vendors to guarantee that unsupported interface implementations will
not be used with hardware types they define. This is done by having a
hardware type list all interfaces it supports.
Implementing the solution in the idrac
hardware type
contributes toward making it the one Dell EMC driver for its bare metal
servers with iDRACs and their value added implementations of the IPMI,
Redfish, and WS-Man management protocols. It also aligns with the goals
of the reform. That is what operators have come to expect.
Here are the details of the proposal.
Define two new groups of interface implementations with entrypoints named
idrac-redfish
andidrac-wsman
. Theidrac-redfish
entrypoints refer to Redfish interface implementations which are compatible with the iDRAC, presently those of themanagement
andpower
hardware interfaces. Theidrac-wsman
entrypoints are new names for the legacyidrac
entrypoints. The legacyidrac
entrypoints are left unchanged. For example:ironic.hardware.interfaces.management = ... idrac = ironic.drivers.modules.drac.management:DracManagement idrac-redfish = ironic.drivers.modules.drac.management:DracRedfishManagement idrac-wsman = ironic.drivers.modules.drac.management:DracWSManManagement ... redfish = ironic.drivers.modules.redfish.management:RedfishManagement
Declare
idrac
hardware type support for theidrac
,idrac-redfish
, andidrac-wsman
interface implementations.idrac
continues to have the highest priority by being first in itssupported_<INTERFACE>_interfaces
lists. Here<INTERFACE>
is a type of hardware interface:inspect
,management
,power
, etc. For example:class IDRACHardware(generic.GenericHardware): ... @property def supported_management_interfaces(self): return [management.DracManagement, management.DracWSManManagement, management.DracRedfishManagement] ...
Note
The property uses classes, not instances nor entrypoint names. The example assumes the required modules are imported.
New
idrac-redfish
entrypoints are defined by new Python classes, because using the generic, vendor-independent Redfish classes would make theredfish
entrypoints synonyms foridrac-redfish
and supported. A later requirement to change the name of an entrypoint's Python class to resolve a Dell EMC-specific incompatibility or introduce vendor value added, which would eliminate support forredfish
, could be a breaking change. The new Python classes are derived from the generic, vendor-independent Redfish classes.New
idrac-wsman
entrypoints are defined by new Python classes. Those classes are created by renaming the classes for the legacyidrac
entrypoints fromDrac<INTERFACE>
toDracWSMan<INTERFACE>
. Here<INTERFACE>
refers to a type of hardware interface:Inspect
,Management
,Power
, etc.The legacy
Drac<INTERFACE>
classes are redefined by simply deriving them from the newDracWSMan<INTERFACE>
classes. For example:class DracManagement(DracWSManManagement): pass
That makes the legacy
Drac<INTERFACE>
classes aliases for the newDracWSMan<INTERFACE>
classes. Any bug fixes or features added to the WS-Man interface implementations are available from both theidrac
andidrac-wsman
entrypoints. Having separate classes for the two groups of entrypoints makes it possible to subsequently add logic that implements deprecation of the legacyidrac
entrypoints by emitting a log message and similar.
Alternatives
- We could change the lowest layer of
python-dracclient
to support Redfish, in addition to WS-Man. However, we expect it would be challenging to providepython-dracclient
APIs and workflows which abstract the very different Redfish and WS-Man technologies. Redfish's interface is RESTful, while WS-Man is a Simple Object Access Protocol (SOAP). APIs and workflows would likely need to be changed or newly defined. That would require substantial modification of the existingidrac
interface implementations. - We could maintain the status quo split of the
idrac
hardware type for WS-Man andredfish
hardware type for Redfish. However, that would not promote and accelerate the use of Redfish among operators with Dell EMC bare metal servers today, becauseredfish
does not offer everythingidrac
does. That also would not support resolving Dell EMC vendor-specific incompatibilities with the generic, vendor-independentredfish
hardware type nor using Redfish to introduce vendor value added. - We could let the
redfish
interface implementations use Redfish OEM extensions to address vendor-specific incompatibilities and introduce vendor value added. However, that seems inconsistent with the intent that they be generic and vendor-independent.
Data model impact
None
State Machine Impact
None
REST API impact
None
Client (CLI) impact
"ironic" CLI
None
"openstack baremetal" CLI
None
RPC API impact
None
Driver API impact
None
Nova driver impact
None
Ramdisk impact
None
Security impact
None
Other end user impact
None
Scalability impact
None
Performance Impact
None
Other deployer impact
A deployer can add
idrac-redfish
to theenabled_management_interfaces
andenabled_power_interfaces
options to enable those new interface implementations.A deployer can add
idrac-wsman
to theenabled_inspect_interfaces
,enabled_management_interfaces
,enabled_power_interfaces
,enabled_raid_interfaces
, andenabled_vendor_interfaces
to enable those new interface implementations.A deployer must specify properties in the node's
driver_info
field that are needed by Redfish interface implementations, includingredfish_address
,redfish_system_id
,redfish_username
, andredfish_password
, to use theidrac-redfish
interface implementations. That is in addition to the legacy properties theidrac
hardware type has needed indriver_info
--drac_address
,drac_username
, anddrac_password
. :openstack baremetal node create --driver idrac --driver-info \ drac_address=1.2.3.4 --driver-info drac_username=admin --driver-info \ drac_password=password --driver_info redfish_address=https://1.2.3.4 \ --driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \ --driver-info redfish_username=admin --driver-info \ redfish_password=password
See the Redfish driver documentation, iDRAC driver documentation, and Non-goals.
A deployer can specify the new
idrac-redfish
andidrac-wsman
interface implementations on node enrollment:openstack baremetal node create --driver idrac ... --management-interface \ idrac-wsman --power-interface idrac-wsman ...
They can also be set by the following command:
openstack baremetal node set <NODE> --management-interface idrac-redfish \ --power-interface idrac-redfish
They must be enabled as described above.
Developer impact
None
Implementation
Assignee(s)
- Primary assignee:
-
rpioso
- Other contributors:
-
None
Work Items
- Define two new groups of interface implementations with entrypoints
named
idrac-redfish
andidrac-wsman
. - Declare
idrac
hardware type support for theidrac
,idrac-redfish
, andidrac-wsman
interface implementations. - Integration test the changes against Dell EMC bare metal servers.
- Modify the Dell EMC Ironic third-party continuous integration (CI) to cover supported configurations added by this specification.
- Update the iDRAC driver documentation.
Dependencies
This specification is related to the Driver composition reform.
It specifically targets Dell EMC bare metal servers equipped with an
iDRAC and managed by the idrac
hardware type.
Testing
This is not testable in the gate given current limitations on the availability of the specific hardware required.
The mitigation plan is to add coverage to the Dell EMC Ironic third-party CI for supported configurations added by this specification that we expect to be common.
Upgrades and Backwards Compatibility
This change is designed to be backwards compatible. The legacy
idrac
interface implementation entrypoints will be
supported for at least some time. A separate story will cover their
deprecation.
We will recommend switching to the appropriate new
idrac-redfish
and idrac-wsman
interface
implementation entrypoints as soon as it is possible.
Documentation Impact
The iDRAC driver documentation is updated to:
- describe switching from the legacy
idrac
interface implementation entrypoints to the newidrac-redfish
andidrac-wsman
entrypoints, - reflect the changes to the supported interface implementations, and
- inform that a node configuration with a mix of Redfish and WS-Man
management
andpower
interface implementations is not supported.
References
- OpenStack software projects:
- Related Ironic specifications:
- Documentation:
- Standards:
Footnotes
See the introduction paragraph of the Ironic Driver composition reform.↩︎
See the Introduction subsection in the Proposed change section of the Ironic Driver composition reform.↩︎