Power fault recovery
https://storyboard.openstack.org/#!/story/1596107
This spec proposes adding a new node field to reflect any faults detected by the system. For nodes put into maintenance mode due to power-sync failures, this proposes a mechanims to try to recover the nodes from the failure.
Problem description
Currently, ironic's API and data model do not differentiate between ironic setting maintenance on a node (for instance, when cleaning fails, or when the power status loop cannot contact the BMC) and an operator setting maintenance on a node (an explicit API action).
This situation makes it difficult to apply any power fault recovery mechanism.
Proposed change
A string field named fault
will be added to ironic's
data model for a Node. It will be used to record any detected
faults.
The field will be set to one of the following values, depending on the situation (when ironic puts the node into maintenance due to one of these):
power failure
: when a node is put into maintenance due to power sync failures that exceed max retries.clean failure
: when a node is put into maintenance due to failure of a cleaning operation.rescue abort failure
: when a node is put into maintenance due to failure of cleaning up during rescue abort.None: there is no fault detected for the node; this is the default value. Since the field is set to a fault when ironic puts the node into maintenance due to a fault, it gets set to None when the node is taken out of maintenance (by ironic or the user).
For nodes that were in maintenance prior to upgrading to this release, the field will also be None, since we don't know for sure, if (or what) there had been a fault. Even if there had been, we don't know whether the operator wants the node in maintenance for other reasons as well.
A periodic task will be added to the conductor. This will operate on
nodes with node.fault == power failure
. It will try to get
the node's power state. If successful, the node will be taken out of
maintenance.
An integer configuration option named
[conductor]power_failure_recovery_interval
will be added.
This is the interval (number of seconds) between each run of the
periodic task. The default value is 300 seconds (5 minutes). Setting it
to 0 will disable power fault recovery.
Alternatives
Proposals have already been made and rejected to use a combination of maintenance being set and a given maintenance_reason or last_error to do self-healing due to inconsistency.
Specific faults support1 is proposed but it's too big and to-date, no consensus has been reached on it.
An earlier version of this spec had proposed a
maintenance_type
field for the node, instead of a
fault
field. We prefer the fault
field since
it better reflects that it is about faults.
maintenance_type
caused the field to be tied in with the
existing maintenance
and maintenance_reason
fields. Using fault
makes it distinct from
maintenance
; it will make it easier to move forward in the
future, should we decide to provide more enhancements that are
fault-related, or to separate the notion and handling of faults from
maintenance (which some would argue should only be
operator-initiated).
Data model impact
A string field named fault
will be added to ironic's
node table.
The field will be added to Node
object; object version
will be incremented.
State Machine Impact
None
REST API impact
The field fault
will be added to Node
API
object, ironic API version will be bumped.
Node-related API endpoints will be affected:
- POST /v1/nodes
- GET /v1/nodes
- GET /v1/nodes/detail
- GET /v1/nodes/{node_ident}
- PATCH /v1/nodes/{node_ident}
For requests with older microversion, node.fault
is
hidden from the response. This will be done in the
hide_fields_in_newer_versions()
.
Field fault
is read-only from the API, and can only be
modified internally. Any POST/PATCH request to Node with
fault
set will get 400 (Bad Request).
There is no other impact to API behaviors.
Client (CLI) impact
"ironic" CLI
None
"openstack baremetal" CLI
The CLI will be updated to support field fault
, guarded
by ironic API microversion.
RPC API impact
None
Driver API impact
None
Nova driver impact
None, although we should update the ironic-virt driver code to also
look at this new node.fault field, in addition to the
node.maintenance
field.
Ramdisk impact
None
Security impact
None
Other end user impact
None
Scalability impact
None
Performance Impact
If the periodic task for recovery is enabled, it will consume some resources on conductor node.
More will be consumed in an environment containing some nodes in maintenance due to power failure.
Other deployer impact
A new option [conductor]power_failure_recovery_interval
is introduced to support power failure recovery. The default value is
300 (5 minutes), you have to set to 0 if this feature is not needed.
Developer impact
None
Implementation
Assignee(s)
- Primary assignee:
-
kaifeng
- Other contributors:
-
dtantsur
Work Items
- Update db layer to include the
fault
field. - Change places where nodes enter/leave maintenance, to set
fault
accordingly. - Add
[conductor]power_failure_recovery_interval
option to ironic configuration, add periodic task to handle power recovery. - API change.
Dependencies
None
Testing
The feature will be covered by unit tests, API change will be covered by tempest test.
Upgrades and Backwards Compatibility
ironic API change is guarded by microversion.
When upgrading, any nodes in maintenance will have
node.fault
set to None. This is because there is no
easy/guaranteed way to determine if a node had been (previously) put
into maintenance due to one of our internal faults. Furthermore, even if
we could determine whether it was due to a fault, we don't know whether
the operator wants to keep the node in maintenance for other reasons
besides the fault.
Should the operator want to take advantage of the power fault recovery mechanism, they could take the nodes out of maintenance. If there are still issues, ironic will do its thing -- detect the fault and try to recover.
Documentation Impact
- Update api-reference.
- New option will be generated by config generator.