@ -136,7 +136,7 @@ ScaleIO section contains the following info to fill in:
* Gateway IP address - IP address of ScaleIO gateway * Gateway IP address - IP address of ScaleIO gateway
* Gateway port - Port of ScaleIO gateway * Gateway port - Port of ScaleIO gateway
* Gateway user - User to access ScaleIO gateway * Gateway user - User to access ScaleIO gateway
* Gateway password - Password to access ScaleIO gateway * Admin password - Password to access ScaleIO gateway
* Protection domain - The protection domain to use * Protection domain - The protection domain to use
* Storage pools - Comma-separated list of storage pools * Storage pools - Comma-separated list of storage pools
@ -160,7 +160,12 @@ ScaleIO section contains the following info to fill in:
* XtremCache storage pools - List of storage pools which should be cached with XtremCache. * XtremCache storage pools - List of storage pools which should be cached with XtremCache.
* Capacity high priority alert - Threshold of the non-spare capacity of the Storage Pool that will trigger a high-priority alert, in percentage format. * Capacity high priority alert - Threshold of the non-spare capacity of the Storage Pool that will trigger a high-priority alert, in percentage format.
* Capacity critical priority alert - Threshold of the non-spare capacity of the Storage Pool that will trigger a critical-priority alert, in percentage format. * Capacity critical priority alert - Threshold of the non-spare capacity of the Storage Pool that will trigger a critical-priority alert, in percentage format.
* Use RAM cache (RMCache) - Enable/Disable use of SDS Servers RAM for caching storage devices in a Storage Pool.
* Passthrough RMCache storage pools - List of Storage Pools to be cached in SDS Servers RAM in passthrough mode (if the 'Use RAM cache (RMCache)' option is enabled)
* Cached RMCache storage pools - List od Storage Pools to be cached in SDS Servers RAM in cached mode (if the 'Use RAM cache (RMCache)' option is enabled)
* Glance images on ScaleIO - Enable/Disable ScaleIO backend for Glance images (It uses cinder backend in Glance to store images on ScaleIO).
This option is available since MOS9.0.
Configuration of disks for allocated nodes: Configuration of disks for allocated nodes:
The devices listed in the "Storage devices" and "XtremCache devices" should be left unallocated for ScaleIO SDS to work. The devices listed in the "Storage devices" and "XtremCache devices" should be left unallocated for ScaleIO SDS to work.

Binary file not shown.

Before

Width:  |  Height:  |  Size: 261 KiB

After

Width:  |  Height:  |  Size: 268 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 241 KiB

After

Width:  |  Height:  |  Size: 329 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 202 KiB

After

Width:  |  Height:  |  Size: 206 KiB